Sistematski pregled / meta-analiza 2024
Opća medicina i istraživanja

Preciznost postavljanja implantata uz kompjuterski potpomognutu statičku, dinamičku i robotsku hirurgiju: sistematski pregled i meta-analiza kliničkih ispitivanja.

BMC oral health

Bosanski prijevod

Sažetak istraživanja

Ovaj sistematski pregled istražuje tačnost kompjuterizovanog vođenog postavljanja implantata, uključujući kompjuterski potpomognutu statičku, dinamičku i robotsku hirurgiju. Elektronska pretraga do 28. februara 2023. godine obavljena je korištenjem baza podataka PubMed, Embase i Scopus korištenjem pojmova za pretraživanje "hirurgija", "kompjuterski potpomognuta", "dinamička kompjuterski potpomognuta", "robotske hirurške procedure" i "dentalni implantati". Varijable ishoda bile su odstupanja uključujući 3D-koronalne, apikalne i ugaone devijacije implantata. Članci su selektivno preuzimani prema kriterijima uključivanja i isključivanja, a podaci su kvantitativno meta-analizom kako bi se potvrdili rezultati studije. Šezdeset sedam članaka je konačno identificirano i uključeno u analizu. Poređenje tačnosti otkrilo je ukupno srednje odstupanje na ulaznoj tački od 1,11 mm (95% CI: 1,02-1,19) i 1,40 mm (95% CI: 1,31-1,49) na vrhu, a ugao je bio 3,51˚ (95% CI: 3,72). Među kompjuterizovanim vođenim postavljanjem implantata, robotski sistem je imao tendenciju da pokaže najmanju devijaciju (0,81 mm u koronalnoj devijaciji, 0,77 mm u apikalnoj devijaciji i 1,71˚ u ugaonoj devijaciji). Nisu nađene značajne razlike između tipa luka i rada zakrilca u slučajevima dinamičke navigacije. Potpuno vođeni protokol pokazao je značajno viši nivo tačnosti u poređenju sa protokolom vođenim pilotom, ali nije pokazao nikakvu značajnu razliku u poređenju sa delimično vođenim protokolom. Upotreba kompjuterizirane tehnologije klinički potvrđuje da operateri mogu precizno postaviti implantate u tri smjera. Nekoliko studija se slaže da je potpuno vođeni protokol zlatni standard u kliničkoj praksi.

Prikaži originalni naslov i sažetak na engleskom

Accuracy of implant placement with computer-aided static, dynamic, and robot-assisted surgery: a systematic review and meta-analysis of clinical trials.

This systematic review explores the accuracy of computerized guided implant placement including computer-aided static, dynamic, and robot-assisted surgery. An electronic search up to February 28, 2023, was conducted using the PubMed, Embase, and Scopus databases using the search terms "surgery", "computer-assisted", "dynamic computer-assisted", "robotic surgical procedures", and "dental implants". The outcome variables were discrepancies including the implant's 3D-coronal, -apical and -angular deviations. Articles were selectively retrieved according to the inclusion and exclusion criteria, and the data were quantitatively meta-analysed to verify the study outcomes. Sixty-seven articles were finally identified and included for analysis. The accuracy comparison revealed an overall mean deviation at the entry point of 1.11 mm (95% CI: 1.02-1.19), and 1.40 mm (95% CI: 1.31-1.49) at the apex, and the angulation was 3.51˚ (95% CI: 3.27-3.75). Amongst computerized guided implant placements, the robotic system tended to show the lowest deviation (0.81 mm in coronal deviation, 0.77 mm in apical deviation, and 1.71˚ in angular deviation). No significant differences were found between the arch type and flap operation in cases of dynamic navigation. The fully-guided protocol demonstrated a significantly higher level of accuracy compared to the pilot-guided protocol, but did not show any significant difference when compared to the partially guided protocol. The use of computerized technology clinically affirms that operators can accurately place implants in three directions. Several studies agree that a fully guided protocol is the gold standard in clinical practice.

Autorstvo i publikacija

Autori

Khaohoen A, Powcharoen W, Sornsuwan T, Chaijareenont P, Rungsiyakull C, Rungsiyakull P.

Časopis
BMC oral health
Vrste publikacije
Meta-analiza, Istraživački članak, Sistematski pregled, Članak u časopisu
Licenca
CC BY
Citiranja u Europe PMC
45
Provjerljivi identifikatori

Izvorni podaci

DOI
10.1186/s12903-024-04033-y
PMID
38509530
PMCID
PMC10956322
Provjereno
2026-07-26
Otvori cijeli rad u Europe PMC
Napomena o bosanskom prijevodu

Naslov i sažetak prevedeni su automatski i prijevod može sadržavati netačnosti ili neprecizne stručne izraze. Za sve detalje, citiranje i medicinsko tumačenje pregledajte originalnu englesku verziju članka. Ne donosite zdravstvene odluke samo na osnovu ovog prijevoda.

Pregledaj originalni članak na engleskom
Istraživački zapis služi za informiranje i istraživanje. Ne zamjenjuje medicinski savjet, dijagnozu ili preporuku liječenja.