Sistematski pregled / meta-analiza 2018
Opća medicina i istraživanja

Efikasnost hiperbaričnog kiseonika kod pacijenata sa idiopatskim iznenadnim senzorneuralnim gubitkom sluha: sistematski pregled.

European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery

Bosanski prijevod

Sažetak istraživanja

Cilj Procijeniti učinkovitost hiperbaričnog kisika u liječenju pacijenata sa idiopatskim iznenadnim senzorneuralnim gubitkom sluha (ISSHL). Izvori podataka An Embase, MEDLINE i Cochrane pretraga su korišteni za identifikaciju različitih kliničkih ispitivanja o liječenju ISSHL-a. Uključene su studije koje su objavljene između 2002. i 2018. godine i napisane na engleskom, holandskom ili njemačkom jeziku. Pojmovi za pretragu uključivali su sinonime za idiopatski iznenadni gubitak sluha. Sinteza podataka Ukupno je identifikovano 16 članaka koji se odnose na hiperbaričnu terapiju kiseonikom. Svi pacijenti su evaluirani audiometrijom čistog tona. Najveći dio slučajeva je imao jednostrani gubitak sluha (bilateralni gubitak sluha manji od 5%). U nekoliko studija, prosjek srednjeg povećanja sluha na pet uzastopnih frekvencija bio je značajno veći u grupi na terapiji hiperbaričnim kiseonikom (HBO) i sistemskim steroidima (SS) kod pacijenata sa teškim ili dubokim oštećenjem sluha. Zabilježili su značajan učinak liječenja (p = 0,005) terapije HBO + SS na pacijente s početnim gubitkom sluha od ≥ 81 dB.

Zaključci Na cijeloj grupi pacijenata sa ISSHL nije dokazana značajna razlika između interventne i kontrolne grupe. Međutim, kod pacijenata sa teškim ili teškim oštećenjem sluha sa ISSHL, uočena je značajna korist u intervencijskoj grupi. Ovi rezultati vjerovatno ukazuju da bi dodavanje HBO steroidnim terapijama moglo biti od koristi u slučajevima ozbiljnog i dubokog oštećenja sluha.

Prikaži originalni naslov i sažetak na engleskom

The effectiveness of hyperbaric oxygen in patients with idiopathic sudden sensorineural hearing loss: a systematic review.

Objective To evaluate the effectiveness of hyperbaric oxygen in the treatment of patients with idiopathic sudden sensorineural hearing loss (ISSHL). Data sources An Embase, MEDLINE and Cochrane search were utilised to identify various clinical trials on the treatment of ISSHL. Studies that were published between 2002 and 2018 and written in the English, Dutch or German language were included. Search terms included synonyms for idiopathic sudden hearing loss. Data synthesis A total of 16 articles were identified regarding hyperbaric oxygen therapy. All patients were evaluated with pure-tone audiometry. A major part of the cases presented with unilateral hearing loss(bilateral hearing loss less than 5%). In several studies, the average of the mean hearing gain at five contiguous frequencies was significantly higher in the hyperbaric oxygen (HBO) therapy and systemic steroid (SS) group in patients with severe or profound hearing impairment. They recorded a significant treatment effect (p = 0.005) of HBO + SS therapy on patients with an initial hearing loss of ≥ 81 dB.

Conclusions On the whole group of ISSHL patients, no significant difference was demonstrated between the intervention and control group. However, in severe or profound hearing-impaired ISSHL patients, significant benefit was observed in the intervention group. These results likely indicate that adding HBO to steroid therapies might be of benefit in cases of severe and profound hearing impairment.

Autorstvo i publikacija

Autori

Eryigit B, Ziylan F, Yaz F, Thomeer HGXM.

Časopis
European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery
Vrste publikacije
Sistematski pregled, Pregledni članak, Članak u časopisu
Licenca
CC BY
Citiranja u Europe PMC
36
Provjerljivi identifikatori

Izvorni podaci

DOI
10.1007/s00405-018-5162-6
PMID
30324404
PMCID
PMC6244669
Provjereno
2026-07-26
Otvori cijeli rad u Europe PMC
Napomena o bosanskom prijevodu

Naslov i sažetak prevedeni su automatski i prijevod može sadržavati netačnosti ili neprecizne stručne izraze. Za sve detalje, citiranje i medicinsko tumačenje pregledajte originalnu englesku verziju članka. Ne donosite zdravstvene odluke samo na osnovu ovog prijevoda.

Pregledaj originalni članak na engleskom
Istraživački zapis služi za informiranje i istraživanje. Ne zamjenjuje medicinski savjet, dijagnozu ili preporuku liječenja.