Koncentracija laktoferina u ljudskim suzama i očnim bolestima: meta-analiza.
Investigative ophthalmology & visual science
Sažetak istraživanja
Svrha Procijeniti potencijal laktoferina (Lf) kao dijagnostičkog biomarkera za očne bolesti koristeći metaanalitički pristup.
Metode Sve originalne studije koje su izvještavale o procjeni prosječne koncentracije Lf kod zdravih subjekata i onih zahvaćenih očnim bolestima pretražene su do marta 2020. Metoda DerSimoniana i Lairda korištena je za izračunavanje prosječne razlike nasumičnih efekata i odgovarajućeg intervala pouzdanosti (CI) od 95% u koncentraciji Lf između zdravih ispitanika i onih koji su zahvaćeni suvim okom (Symejögren Diadrom) retinopatija, odvojeno. Prisustvo heterogenosti između studija procijenjeno je korištenjem Cochranovog Q testa i I2 indeksa. Izvršene su stratificirane analize za procjenu potencijalnih izvora heterogenosti i utjecaja i kumulativne analize za procjenu robusnosti dobijenih rezultata. Pristrasnost publikacije je također procijenjena korištenjem dijagrama lijevka i Eggerovog testa.
Rezultati Objedinjene srednje razlike u koncentracijama Lf između zdravih subjekata i onih sa DE, Sjogrenovim sindromom i dijabetičkom retinopatijom bile su 0,62 (95% CI, 0,35-0,89) za DE, 3,78 (95% CI, -6,64 do 14,19, -9,0% do 14,19) i -9,0% do CI 4.39). Što se tiče DE, stratifikovana analiza je pokazala da je geografsko područje (P vrijednost Q test
Zaključci Rezultati trenutne meta-analize sugeriraju da je nivo Lf u suzama dobar kandidat za dijagnostički biomarker sindroma suhog oka.
Prikaži originalni naslov i sažetak na engleskom
Lactoferrin Concentration in Human Tears and Ocular Diseases: A Meta-Analysis.
Purpose To evaluate the potential of lactoferrin (Lf) as a diagnostic biomarker for ocular diseases using a meta-analytic approach.
Methods All original studies reporting an estimate of the average Lf concentration in healthy subjects and those affected by ocular diseases were searched up to March 2020. The DerSimonian and Laird method was used to calculate the random effects pooled mean difference and the corresponding 95% confidence interval (CI) in Lf concentration between healthy subjects and those affected by dry eye (DE), Sjögren syndrome (SS), and diabetic retinopathy, separately. The presence of between-study heterogeneity was evaluated using the Cochran's Q test and the I2 index. Stratified analyses were performed to assess potential sources of heterogeneity and influence and cumulative analyses to evaluate the robustness of the results obtained. Publication bias was also evaluated using funnel plot and the Egger's test.
Results The pooled mean differences in Lf concentrations between healthy subjects and those with DE, Sjögren syndrome, and diabetic retinopathy were respectively 0.62 (95% CI, 0.35-0.89) for DE, 3.78 (95% CI, -6.64 to 14.17), and 0.19 (95% CI, -4.00 to 4.39). Regarding DE, the stratified analysis showed that geographical area (P value Q test
Conclusions The results of the current meta-analysis suggest that Lf level in tears is a good candidate as dry eye syndrome diagnostic biomarker.
Izvorni podaci
- DOI
- 10.1167/iovs.61.12.9
- PMID
- 33035290
- PMCID
- PMC7552940
- Provjereno
- 2026-07-26
Naslov i sažetak prevedeni su automatski i prijevod može sadržavati netačnosti ili neprecizne stručne izraze. Za sve detalje, citiranje i medicinsko tumačenje pregledajte originalnu englesku verziju članka. Ne donosite zdravstvene odluke samo na osnovu ovog prijevoda.
Pregledaj originalni članak na engleskom